Switch Mode Transformers photo

1.5 kW Switchmode Transformer

West Coast Magnetics' 407 series transformers have been designed for power use including linear and switch mode applications. The power handling capability is as high as 1500 watts in bipolar topologies. This type of transformer is often used in forward converter topologies. Recommended frequency of operation is as low as 10 kHz and as high as 500 kHz. This E-core series is based on popular lamination sizes. As a result 60 Hz transformers and inductors can be constructed from this geometry by replacing the ferrite cores with silicon steel laminations.

Download Product Sheet PDF

Request price and delivery information.


Design Constants
Size CodeAl ungapped)Al single gapAe core area (mm2)le magnetic path length (mm)Ve core volume (mm3)Wa bobbin winding area (mm2)WaAc core area x winding area (mm4)Bobbin window width(mm)Bobbin window height(mm)Mean length per turn (mm)
E 342950±25%Any84.969.6590794.88,04816.55.773.5
E 415060±25%Any156.777.612,165101.015,82618.15.785.6
E 475100±25%Any233.089.020,700119.327,79621.15.799.1
E 566700±25%Any340.0107.036,400189.064,26026.27.2117.6

Power Curve Assumptions:

  1. Push/Pull circuit topology
  2. Bobbin Window area utilization = 40%
  3. Flux density (B) chosen so that core losses at all Frequencies except 60 Hz are 70 mW/cm3.
output frequency

Output Power vs Frequency of Operation (Watts)

Size Code60Hz25 kHz50 kHz100 kHz250 kHz500 kHz
E 343.582109145205246
E 417.0166221293415498
E 4712.0265352469663795
E 5622.055373597813821659
schematics

click image to enlarge

  • * square pin

    • Size CodeLWHld
      E341.25/31.81.49/37.81.05/26.7.125/3.2.025/.64
      E411.40/35.61.69/42.91.15/29.2.150/3.8.025/.64
      E471.60/40.61.90/48.31.32/33.5.135/3.4.025/.64
      E561.90/48.32.27/57.71.58/40.1.165/4.2.025/.64

      Note: L,W, H are maximum dimensions with mounting hardware.

      Note: l is nominal pin length. Allow for ±10% variation in this dimension.

      Note: All materials of construction minimum Class B 130 degrees C rated.

      Dimensions: Inches/mm

pcb layouts

click image to enlarge


Note: All materials of construction minimum Class B 130 degrees C rated.

Dimensions: Inches/mm

notes

Notes:

  1. Reduce power rating in Table above by 50% for forward and flyback converter topologies.
  2. Final sizing of the transformer will depend on a number of interrelated variables. The data in the above table should be considered a starting point only.
  3. If safety agency is required, the final size may be significantly
    larger than the data in the table would indicate.