Switch Mode Transformers photo

Switchmode Power Transformer

West Coast Magnetics' 404 series is ideal for use in switch mode power supply applications. These transformers extend the output power range available beyond the West Coast Magnetics' 401 and 402 series transformers up to 500 Watts. The geometry of the 404 series core and bobbin provides a uniform winding area around the magnetic circuit which provides greater efficiency than other E_core designs. The material has also been designed to maximize inter-winding isolation, making the 404 series a good choice when safety agency compliance is important.

Download Product Sheet PDF

Request price and delivery information.


Design Constants
Size CodeAl (ungapped, min.)Al single gapAe core area (mm2)le magnetic path length (mm)Ve core volume (mm3)Wa bobbin winding area (mm2)WaAc core area x winding area (mm4)Bobbin window width (mm)Bobbin window height (mm)Mean length per turn (mm)
ETD 2916001607672550095722019.44.953
ETD 341900160977976001231193021.05.960
ETD 39210025012592115001772212525.96.869
ETD 442600250173104178002143702229.77.277
ETD 493000400211114240002735760332.78.385

Power Curve Assumptions:

  1. Push/Pull circuit topology
  2. Bobbin Window area utilization = 40%
  3. Flux density (B) chosen so that core losses at all Frequencies are 70mW/cm3.
output frequency

Output Power vs Frequency of Operation (Watts)

Size Code25 kHz50 kHz100 kHz250 kHz500 kHz
ETD 297398131185221
ETD 34115153204287344
ETD 39198264352495593
ETD 44311415554778932
ETD 4946061281711461374
schematics

click image to enlarge

  • * square pin

    • Size CodeLWHld
      ETD291.39/35.31.39/35.31.00/25.4.25/3.2.028*/.71
      ETD341.68/42.71.58/40.11.38/35.1.200/5.1.039/1.0
      ETD391.90/48.31.80/45.7 1.48/37.6.200/5.1.039/1.0
      ETD442.08/52.82.00/50.81.58/40.1.200/5.1.039/1.0
      ETD492.28/57.92.18/55.41.68/42.7.200/5.1.039/1.0

      Note: All materials of construction minimum Class B 130 degrees C rated.

      Dimensions: Inches/mm

pcb layouts

click image to enlarge


Note: All materials of construction minimum Class B 130 degrees C rated.

Dimensions: Inches/mm

notes

Notes:

  1. Reduce power rating in Table above by 50% for forward and flyback converter topologies.
  2. Final sizing of the transformer will depend on a number of interrelated variables. The data in the above table should be considered a starting point only.
  3. If safety agency is required, the final size may be significantly larger than the data in the table would indicate.