PC Mount Isolation Transformers photo

PC Mount Isolation Transformer

West Coast Magnetics' 804 series power transformer is designed for 50/60 Hz operation. This transformer uses a split bobbin construction with a shroud resulting in high isolation between windings. The transformer package is rated for a 3750 Vac Hypot with power levels ranging from 2.8 VA to 36 VA.

Download Product Sheet PDF

Request price and delivery information.


Design Constants
Size CodeAe core area (cm2)le magnetic path length (cm)Ve core volume (cm3)Wa bobbin winding area (cm2)Wa Ac core area x winding area (cm4)Bobbin winding width (mm)Bobbin winding height (mm)Mean length per turn (cm)Surface area (cm2)VA RatingWeight (kg)
804-11.218.269.83.731.8856.605.547.6572.80.12
804-21.618.2613.10.7311.1776.605.548.2623.80.15
804-32.529.5323.64.8862.237.925.599.5837.70.25
804-43.6311.4341.011.515.4910.417.2611.212017.50.43
804-53.5213.3446.262.278.0012.838.8611.714724.00.53
804-64.8415.2471.892.6812.9612.8310.4413.519536.00.75

*NOTE: VA rating based on 60 Hz operation

part views

click image to enlarge


Part NumberHLWX1X2Yld(square)
804-11.09/2.771.63/4.141.32/3.35.250/.64.200/.511.000/2.54.30/.76.025/.064
804-21.35/3.431.63/4.141.32/3.35.400/1.02.200/.511.000/2.54.30/.76.025/.064
804-31.37/3.481.88/4.781.57/3.99.400/1.02.200/.511.128/2.87.30/.76.036/.091
804-41.59/4.042.30/5.841.88/4.78.400/1.02.200/.511.436/3.65.30/.76.036/.091
804-51.59/4.042.63/6.682.25/5.72.275/.69.275/.701.650/4.19.30/.76.045/.114
804-61.83/4.653.05/7.752.55/6.48.300/.76.300/.761.866/4.74.30/.76.045/.114

Note: All materials of construction minimum Class B 130 degrees C rated.

Dimensions: Inches/mm

pcb layouts

Part NumberX1X2
804-1.250/.64.200/.51
804-2.400/1.02.200/.51
804-3.400/1.02.200/.51
804-4.400/1.02.200/.51
804-5.275/.69.275/.70
804-6.300/.76.300/.76

Note: All materials of construction minimum Class B 130 degrees C rated.

Dimensions: Inches/mm

| sitemap | © 2008 West Coast Magnetics 4848 Frontier Way, Suite 100, Stockton, CA 95215