60Hz Transformers photo

Chassis Mount 60Hz Power Transformer

WC Magnetics' 60 Hz Transformers are designed for use in low frequency power applications. They feature high efficiency resulting in a compact size. These 60 Hz Transformers also incorporate safety features which make them ideal for international safety applications. Split bobbin construction results in very low capacitance.

Download Product Sheet PDF

Request price and delivery information.


Design Constants
Part NumberAe core area (cm2)le magnetic path length (cm)Surface area cm2Wa bobbin winding area (mm2)WaAc core area x winding area (cm4)Bobbin window width (mm)Bobbin window height (mm)Mean length per turn (cm)Weight (gm)VA Rating
802-1.917.346.21091.376.616.56.7963.2
802-21.217.350.21091.826.616.57.31254.3
802-31.618.362.11162.656.518.18.21656.3
802-42.018.366.91163.316.518.18.82068.0
802-52.529.583.21374.776.421.19.527211
802-63.029.589.01375.716.421.110.132614
802-73.6311.4119.82129.888.126.211.246823
802-84.8411.4133.121213.178.126.212.562431
802-94.9413.3163.033818.339.829.913.074144
802-106.3513.3179.033823.609.829.914.392557
schematics

Note: All materials of construction minimum Class B 130 degrees C rated.

Dimensions: Inches/mm

part views

click image to enlarge


Part NumberLWHFGDeLead Wire
802-11.46/37.11.07/27.21.21/30.71.75/44.52.06/52.4.187/4.74"3/824 AWG
802-21.46/37.11.20/30.51.21/30.71.75/44.52.06/52.4.187/4.74" 3/824 AWG
802-31.72/43.71.20/30.51.39/35.32.0/50.82.38/60.5.187/4.75"3/824 AWG
802-41.72/43.71.40/37.61.39/35.32.0/50.82.38/60.5.187/4.75"3/824 AWG
802-51.96/49.81.31/33.31.65/41.92.375/60.32.81/71.5.187/4.75"3/824 AWG
802-61.96/49.81.45/36.81.65/41.92.375/60.32.81/71.5.187/4.75"3/824 AWG
802-72.33/59.21.58/40.11.97/50.02.81/71.53.25/82.6.187/4.76"1/224 AWG
802-82.33/59.21.86/47.21.97/50.02.81/71.53.25/82.6.187/4.76"1/224 AWG
802-92.73/69.31.82/46.22.38/60.53.125/79.43.69/93.7.187/4.76"1/224 AWG
802-102.73/69.32.21/36.22.38/60.53.125/79.43.69/93.7.187/4.76"1/224 AWG

* Square

Note: Split Primary (Options A & C) functional for 115 VAC/230 VAC modes.
Untapped Secondary (Options B & C) for full wave bridge and regulated linear outputs.

Note: All materials of construction minimum Class B 130 degrees C rated.

Dimensions: Inches/mm

notes

Notes:

  1. These transformers are semi-custom. Choose a schematic and specify input and output voltage, VA Rating and operating frequency with your RFQ.