High Frequency Transformers photo

1 MHz Switchmode Transformer

West Coast Magnetics' 402 series high frequency transformers are intended for use in switch mode power supplies including push/pull, flyback, and forward converter circuits. Output power as high as 257 watts can be achieved in push/pull circuits. All sizes are based on low proŞle E-core geometry and two sizes are offered in surface mount packaging. West Coast Magnetics stocks core material which will accommodate a range of operating frequencies from 10 kHz to 3 MHz.

Download Product Sheet PDF

Request price and delivery information.


Design Constants
Size CodeAl frequency > 500 kHz a.Al frequency ≤ 500 kHz a.Al single gapAl double gapAe core area (mm2)le magnetic path length (mm)Ve core volume (mm3)Wa bobbin winding area (mm2)WaAc core area x winding area (mm4)Bobbin window width (mm)Bobbin window height (mm)Mean length per turn (mm)
EFD-1540085070135153451017.12578.91.9327
EFD-206501200701353147146028.187113.42.138
EFD-2510002000801555857330042.5246516.72.5548
EFD-3010502150801556968470054.1373320.42.6552

Power Curve Assumptions:

  1. Push/Pull circuit topology
  2. Bobbin Window area utilization = 40%
  3. Flux density (B) chosen so that core losses at all Frequencies are 100 mW/cm3.

a. Al measured for ungapped cores. nH/T2 ± 25%

output frequency

Output Power vs Frequency of Operation (Watts)

Size Code50 kHz100 kHz250 kHz500 kHz1000 kHz2000 kHz3000 kHz
EFD 156.89.31416252017
EFD 2020274247725949
EFD 254967104117180147121
EFD 307096149169257210173
schematics
Part Views and Dimensions
EFD 15 and EFD 20EFD 25 and EFD 30

click image to enlarge

click image to enlarge
Size/CodeABCDEFIJKL
EFD 15.894/22.7.736/18.7.657/16.7.039/1.0.315/8.0.012/0.3.110/2.8.150/3.75.811/20.6.079/2.0
EFD 201.091/27.7.933/23.7.854/21.7.039/1.0.406/10.3.012/0.3.110/2.8.150/3.75 1.01/25.6.079/2.0
Size/CodeACDEFGJKL
EFD 251.024/26.01.024/26.0.031/0.8.511/13.0.071/1.8.138/3.5.197/5.0.886/22.5.052/1.3
EFD 301.220/31.01.220/31.0.031/0.8.511/13.0.071/1.8.138/3.5.197/5.01.083/27.5 .052/1.3

Note: All materials of construction minimum Class B 130 degrees C rated.

Dimensions: Inches/mm

notes

Notes:

  1. Reduce power rating in Table above by 50% for forward and flyback converter topologies.
  2. Final sizing of the transformer will depend on a number of interrelated variables. The data in the above table should be considered a starting point only.
  3. If safety agency is required, the final size may be significantly
    larger than the data in the table would indicate.