1 MHz Power Transformer

West Coast Magnetics' 401 series high frequency transformers are intended for use in switch mode power supplies including push/pull, flyback, and forward converter circuits. Output power as high as 7 watts can be achieved in push/pull circuits. All sizes are based on low profile ER core geometry and all sizes are offered in surface mount packaging. West Coast Magnetics stocks core material which will accommodate a range of operating frequencies from 10 kHz to 3 MHz.

Download Product Sheet PDF

Request price and delivery information.


Design Constants
Size CodeAl frequency > 500 kHz a.Al frequency ≤500 kHz a.Al single gapAl double gapAe core area (mm2)le magnetic path length (mm)Ve core volume (mm3)Wa bobbin winding area (mm2)WaAc core area x winding area (mm4)Bobbin window width (mm)Bobbin window height (mm)Mean length per turn (mm)
ER 9.5525950701358.614.01203.126.72.151.4318
ER 1172514007013511.714.61703.338.62.001.6522
ER 14.5---16007013517.619.03305.596.82.002.7527
output frequency

Output Power vs Frequency of Operation (Watts)

Size Code50kHz100kHz250kHz500kHz1000kHz2000kHz3000kHz
ER 9.50.91.32.02.33.52.82.3
ER 111.31.82.83.14.83.93.2
ER 14.52.83.96.16.9---- not available ----
    Power Curve Assumptions:
  1. Push/Pull circuit topology
  2. Bobbin Window area utilization = 40%
  3. Flux density (B) chosen so that core losses at all frequencies are 100 mW/cm3.
    a. Al measured for ungapped cores. nH/T2 ± 25%
schematics
ER 9.5ER 11 & ER 14.5

click image to enlarge

click image to enlarge
Size/CodeABCDEFIJKL
ER 9.5.457/11.6.319/8.1.395/10.0.028/0.7.240/6.1.004/0.1.079/2.0.079/2.0.535/13.6.051/1.3
ER 11.480/12.2.362/9.2.460/11.7028/0.7.240/6.1.004/0.1.079/2.0.079/2.0.559/14.2.051/1.3
ER 14.5.630/16.0.472/12.0.600/15.2028/0.7.295/7.5.004/0.1.079/2.0.098/2.5.708/18.0.051/1.3

Note: All materials of construction minimum Class B 130 degrees C rated.

Dimensions: Inches/mm

notes

Notes:

  1. Reduce power rating in Table above by 50% for forward and flyback converter topologies.
  2. Final sizing of the transformer will depend on a number of interrelated variables. The data in the above table should be considered a starting point only.
  3. If safety agency is required, the final size may be significantly larger than the data in the table would indicate.
  4. High frequency material (>500kHz) is available in ER 9.5 andER 11 sizes only.