Switch Mode Transformers photo

100 kHz Power Transformer

West Coast Magnetics' 406 series transformers have been designed for power use including linear and switch mode applications. Gapped cores will support significant amount of DC so this series is ideal for flyback applications. Recommended frequency of operation is as low as 10 kHz and as high as 500 kHz. The 406 series geometry will also support a high level of creepage and clearance and is suited for designs requiring high levels of safety isolation.

Download Product Sheet PDF

Request price and delivery information.


Design Constants
Size CodeAl ungapped)Al single gapAe core area (mm2)le magnetic path length (mm)Ve core volume (mm3)Wa bobbin winding area (mm2)WaAc core area x winding area (mm4)Bobbin window width(mm)Bobbin window height(mm)Mean length per turn (mm)
E 201350±25%Any32.146.3149034109112.52.741.2
E 251440minAny38.548.5187041157910.34.054.0
E 281800±25%Any52.557.5302061320315.63.950.0
E 301680minAny60.165.6394083498817.34.855.0

Power Curve Assumptions:

  1. Push/Pull circuit topology
  2. Bobbin Window area utilization = 40%
  3. Flux density (B) chosen so that core losses at all Frequencies are 100mW/cm3.
output frequency

Output Power vs Frequency of Operation (Watts)

Size Code25 kHz50 kHz100 kHz250 kHz500 kHz
E 202125335157
E 252834457179
E 28526285129144
E 307893124194217
schematics

click image to enlarge

  • * square pin

    • Size CodeLWHld
      E20.85/21.6.88/22.2.70/17.8.138/3.5.018*/.45
      E25.82/20.81.05/26.70.83/21.1.135/3.4.025*/0.64
      E281.10/27.91.11/28.20.83/21.1.138/3.5.028*/0.71
      E301.23/31.21.23/31.2.79/20.1.120/3.0.030/0.76

      Note: L,W, H are maximum dimensions with mounting hardware.

      Note: d is maximum diameter. This dimension may vary by 15%.

      Note: l is nominal pin length. Allow for ±10% variation in this dimension.

      Note: All materials of construction minimum Class B 130 degrees C rated.

      Dimensions: Inches/mm

pcb layouts

click image to enlarge


Note: All materials of construction minimum Class B 130 degrees C rated.

Dimensions: Inches/mm

notes

Notes:

  1. Reduce power rating in Table above by 50% for forward and flyback converter topologies.
  2. Final sizing of the transformer will depend on a number of interrelated variables. The data in the above table should be considered a starting point only.
  3. If safety agency is required, the final size may be significantly larger than the data in the table would indicate.